Boiler Reset Control Panel with DHW priority for 4 zones of 4-wire valves

List Price:
$1,281.16
Our Price:
$388.23 (You save $892.93)
SKU:
AQ25144B
Brand:
Weight:
9.00 LBS

Quantity:


Product Description

Boiler Reset Control Panel with DHW priority for 4 zones of 4-wire valves (with end switches.)

Features

  • Use with AQ1000 2-wire communicating thermostats or most digital dry contact thermostats.
  • Controls one boiler loop and one mixed temperature loop. 
  • Use of variable speed injection pump or motorized mixing valve for mixed temperature loop control. 
  • 0-10 Vdc modulating output for driving a modulating/condensing boiler or a modulating mixing valve. 
  • Displays of outdoor temperature on all AQ1000 thermostats when used with an AQ12C10 outdoor sensor (included). 
  • Intuitive programming interface and armchair programming (can be programmed at your desk and taken to the job site "ready-to-install") 
  • Customizable control settings and schedules allow for greater level of control and comfort. 
  • Central programming of set points and setback.
  • Controls up to 2 stages of heat from a single thermostat. 
  • Zoning Control for up to four zones as shipped; can be expanded to a total of 16 zones with AQ255 or AQ257 expansion zoning panels, and up to 64 zones by using AQ254 Add-a-Temperature expansion panels. 
  • Outdoor temperature compensation (reset), or Load reset based on indoor temperature feedback. 
  • Zone synchronization through Zone of Greatest Demand control. 
  • Domestic hot water priority and priority override protection. 
  • Line or low-voltage output for zoning equipment (pumps or valves). 
  • Boiler short cycling protection. 
  • Boiler post purge. 
  • Freeze protection. 
  • Pump/valve exercise. 
  • Boiler shock prevention from cold water returning to boiler. 
  • Automated test and purge feature for quick start-up and simplified troubleshooting. 
  • Integral 38 VA transformer with self resetting electronic fuse. 
  • 2 hour power supply (super capacitor) to retain day and time settings during power outage. 
  • Non-volatile EPROM memory retains program settings during power outage.


Specifications

Application Boiler reset control for hydronic zoning system
Thermostat Compatibility AQ1000 Series 2-wire communicating thermostats and most digital thermostats
Setback Program 7 day, up to 2 setback periods/day.
User Interface (Setting, Programming) LCD Display and a 7 button Key Pad
Number of Zones Controlled 4
Boiler (Supply) Max.
Control Temperature (F)
OFF, 120F to 225 F
Boiler (Supply) Max.
Control Temperature (C)
OFF, 49C to 107 C
Boiler Min. Control Temperature (F) OFF, 59F to 180F
Boiler Min. Control Temperature (C) OFF, 15C to 82C
Outdoor Low Design Control
Temperature (F)
-60F to 32F
Outdoor Low Design Control
Temperature (C)
-51 C to 0 C
Return Min. Control Temperature (F) 80 F to 180 F
Return Min. Control Temperature (C) 27C to 82C
Boiler Differential 2F to 41F (1C to 23C), or Auto (minimum 2 minutes on time)
Boiler Heat Post Purge Off, 10 seconds to 30 minutes (factory default is 30 seconds)
Pump/Valve exercise 30 seconds per 2 weeks of space heating inactivity
Power Supply 120V/60Hz
R-C Output (on transformer) 38 VA, 24 Vac Class II
R-C Input (on Control and Zoning Modules) 24 Vac Class II (input on Control and Zoning Modules)
Supply/Return Sensor Lead Length: 10 ft. (3050 mm). 10 kilohm NTC thermistor at 25 C (77 F) ±0.5F (±0.3C) up to 500 ft (150 M) using 18 AWG or larger wire
Auxiliary (Demand) Input External dry contacts connection only
Heat Demand (Thermostat R-W) Input External dry contacts connection only
DHW Demand Input External dry contacts connection only
Boiler (T-T) Output Rating 24 Vac, 0.5A, 12VA
Auxiliary Low Voltage Output Rating 24 Vac, 0.5A, 12VA
B-B Communication Bus Terminals Low voltage, Class II, 2-wire polarity-insensitive, digital communicating link to other Control or Zoning modules.
Zone Module Thermostat input Low voltage, Class II, 2-wire polarity-insensitive, digital communicating with power link to AQ1000 series thermostat.
Boiler Pump Output Rating 120 Vac/250 Vac 5A, 1/3HP
DHW Pump/Valve Output Rating 120 Vac/250 Vac 5A, 1/3HP
Auxiliary Pump Output Rating Dry contact output, 120 Vac/250 Vac 5A, 1/3 HP
Zone Output Contact Rating Pumps: 120 Vac/250 Vac, 5A, 1/3 HP
Zone Output Contact Rating Valves: 24 Vac, 0.5 A, 12 VA
Control and Zoning Panel
Temperature Rating (F)
32 F to 130 F
Control and Zoning Panel
Temperature Rating (C)
0 C to 55 C
Operating Humidity Range (% RH) 5 to 90% RH, non-condensing
Sensor Temperature Rating (F) -58 F to +230 F
Sensor Temperature Rating (C) -50 C to +110 C
Dimensions (in.) 16 1/2 in wide x 8 in. high x 3 3/8 in deep
Dimensions (mm) 42 cm wide x 20.3 cm high x 8.5 cm deep
Weight (kg) 2.6 kg
Weight (lb) 5.7 lbs
Tradeline Value Tradeline
Type of Zoning Devices Controlled Zone valves with end switches
Boiler Design Temperature (F) 80F to 210F
Boiler Design Temperature (C) 26C to 99C
WWSD (Warm Weather Shut Down) Temperature (F) Off, 35 F to 100 F
WWSD (Warm Weather Shut Down) Temperature (C) Off, 1 C to 38 C
Electrical Connections (Line Voltage) Wire-clamp screw terminals, Maximum 2 x 14 AWG each on line voltage terminals
Outdoor Sensor Lead Length: 10 ft. (3050 mm). 10 kilohm NTC thermistor at 25 C (77 F) +/- 0.5F (+/-0.3C) up to 500 ft (150 M) using 18 AWG or larger wire, beta=3892.
Replacement Parts AQ10X38 24 Vac 38 VA transformer
Replacement Parts AQ12C10 outdoor sensor
Replacement Parts AQ12C11 supply/return/mixed loop sensor
Replacement Parts AQ15740B 4-zone valve with end switch expansion module
Replacement Parts AQ15100B boiler reset module
Approvals, Canadian
Standards Association
CSA C/US Certified to CSA and UL Standards, File No. LR76030