Aquatrol Boiler Control Panel with DHW priority for 4 zones of 4-wire valves (with end switches)
| Application | Boiler control for zoned hydronic systems |
| Thermostat Compatibility | AQ1000 Series 2-wire communicating thermostats and most digital thermostats |
| User Interface (Setting, Programming) | DIP Switches |
| Number of Zones Controlled | 4 |
| Boiler Heat Post Purge | 30 seconds (sent to DHW tank or Zone of Greatest Demand - selectable) |
| Pump/Valve exercise | 30 seconds per 2 weeks of space heating inactivity |
| Power Supply | 120V/60Hz |
| R-C Output (on transformer) | 38 VA, 24 Vac Class II |
| R-C Input (on Control and Zoning Modules) | 24 Vac Class II |
| Supply/Return Sensor | Lead Length: 10 ft. (3050 mm). 10 kilohm NTC thermistor at 25 C (77 F) ±0.5F (±0.3C) up to 500 ft (150 M) using 18 AWG or larger wire |
| Heat Demand (Thermostat R-W) Input | External dry contacts connection only |
| DHW Demand Input | External dry contacts connection only |
| Boiler (T-T) Output Rating | 24 Vac, 0.5A, 12VA |
| B-B Communication Bus Terminals | Low voltage, Class II, 2-wire polarity-insensitive, digital communicating link to other Control or Zoning modules. |
| Zone Module Thermostat input | Low voltage, Class II, 2-wire polarity-insensitive, digital communicating with power link to AQ1000 series thermostat. |
| ZR-ZC Contact Rating | 120 to 240 Vac, 1/3 HP |
| Boiler Pump Output Rating | 120 Vac/250 Vac 5A, 1/3HP |
| DHW Pump/Valve Output Rating | 120 Vac/250 Vac 5A, 1/3HP |
| Auxiliary Pump Output Rating | Dry contact output, 120 Vac/250 Vac 5A, 1/3 HP |
| Zone Output Contact Rating | Pumps: 120 Vac/250 Vac, 5A, 1/3 HP |
| Zone Output Contact Rating | Valves: 24 Vac, 0.5 A, 12 VA |
| Control and Zoning Panel Temperature Rating (F) | 32 F to 130 F |
| Control and Zoning Panel Temperature Rating (C) | 0 C to 55 C |
| Operating Humidity Range (% RH) | 5 to 90% RH, non-condensing |
| Sensor Temperature Rating (F) | -58 F to +230 F |
| Sensor Temperature Rating (C) | -50 C to +110 C |
| Dimensions (in.) | 13 in wide x 8 in. high x 3 3/8 in deep |
| Dimensions (mm) | 33 cm wide x 20.3 cm high x 8.5 cm deep |
| Weight (kg) | 2.3 kg |
| Weight (lb) | 4.9 lbs |
| Type of Zoning Devices Controlled | Zone valves with end switches |
| Electrical Connections (Line Voltage) | Wire-clamp screw terminals, Maximum 2 x 14 AWG each on line voltage terminals |
| Outdoor Sensor | Lead Length: 10 ft. (3050 mm). 10 kilohm NTC thermistor at 25 C (77 F) +/- 0.5F (+/-0.3C) up to 500 ft (150 M) using 18 AWG or larger wire, beta=3892. |
| Replacement Parts | AQ15000B boiler control module |
| Replacement Parts | AQ10X38 24 Vac 38 VA transformer |
| Replacement Parts | AQ12C11 supply/return/mixed loop sensor |
| Replacement Parts | AQ15740B 4-zone valve with end switch expansion module |
| Approvals, Canadian Standards Association | CSA C/US Certified to CSA and UL Standards, File No. LR76030 |